Code 5310: “lamp - temperature too high” (Error)

Situation

Solution

Ambient temperature too high.

Check the ambient temperature at the air inlets of the projector. Make sure that the ambient temperature does not exceed 35°C (95°F).

Blocked large dust filter.

Clean the large dust filter or replace with new one. See service manual chapter "Dust Filters".

Blocked small dust filter.

Clean the small dust filter or replace with new one. See service manual chapter "Dust Filters".

Malfunction air extraction system.

Check the condition of the air extraction system. The air extraction system must be capable of removing minimum 4 m³/min (140 CFM) per installed DP2K-E series digital projector.

Note: limit the amount of extraction to a maximum of 5m3/min (180 CFM). Excessive air extraction can dramatically speed up contamination of the projector air inlet filters, hence requiring more regular filter cleaning interventions.

Malfunction system outlet fan.

Check the speed and voltage of the system outlet fan. See User Guide Communicator. Replace any malfunctioning fan.