Situation |
Solution |
|---|---|
|
Disconnected wire unit between the Signal Backplane and the LPS module (reference 4, LPS side and reference 5 Signal backplane side image "Mains and CTRL connection LPS"). |
Reconnect the wire unit between the Signal Backplane and the LPS module. |
|
Disconnected wire unit between the “CTLB IN” and “CTLB OUT” sockets of the LPS units (reference 3 image "Mains and CTRL connection LPS"). |
Reconnect the wire unit between the “CTLB IN” and “CTLB OUT” sockets of the LPS units. |
|
Malfunction of one of the LPS units. The orange LED (Heartbeat) of the malfunction LPS is not blinking. |
Replace the whole LPS module. See "Removing the LPS module". |
|
Defect Signal Backplane. |
Replace the Signal Backplane. See "Replacement of the signal back plane". |
![]() |
|
Mains and CTRL connection LPS |