Code 5985: “dmd green front - temperature sensor short” (Error)

Situation

Solution

Damaged insulation of the wire unit of the temperature sensor which measures the temperature at the front side of the DMD of the green channel. When disconnecting the wire unit (reference 3 image "Red DMD front temperature sensor connection") of the temperature sensor from the Signal backplane the error code is changed to “dmd green front - temperature sensor open”.

  1. Repair the insulation of the wire unit using shrink sleeve

  2. If not repairable, replace the whole Light Processor Unit. Contact Barco for further instructions to repair the malfunction light processor.

Defect temperature sensor which measures the temperature at the front side of the DMD of the green channel.

Replace the whole Light Processor Unit. Contact Barco for further instructions to repair the malfunction light processor.

DMD front temp connection

Red DMD front temperature sensor connection