Situation |
Solution |
|---|---|
|
Wire unit (reference 1 image "Cold mirror fan connection") of the Cold Mirror fan (reference 2 image "Cold mirror fan connection") disconnected. |
Remove the left cover of the projector and check the connection of the wire unit of the fan below the Cold Mirror. |
|
Wire unit of the fan units (reference 5 image "Cold mirror fan connection") disconnected from the Signal Backplane. |
Remove the front cover and front dust filter from the projector and check if the wire unit (reference 5 image "Cold mirror fan connection") is inserted in the Signal Backplane. |
|
Blocked fan (reference 2 image "Cold mirror fan connection"). |
Unblock the fan. Ensure that the fan can turn freely. |
|
Damaged wire unit. |
Check if the wire unit of the fan is not damaged. Repair if possible, otherwise replace with new one. |
|
Malfunction Fan Control board. |
Replace the Fan Control board. See "Removing a board in the card cage". |
|
Fan end of life. |
Replace the fan. See chapter "Cold mirror fan". |
![]() |
|
Cold mirror fan connection |