Code 5305: “dmdgreen - temperature sensor short” (Error)

Situation

Solution

Damaged wire unit of the temperature sensor (Reference SG ) which measures the temperature at therear side of the DMD of the green channel.

  1. Repair the wire unit.

  2. If not repairable, replace the whole Light Processor Unit. ContactBarco for further instructions to repair the malfunction Light ProcessorUnit.

Defect temperature sensor which measures the temperature atthe rear side of the DMD of the green channel. When disconnectingthe wire unit (Reference SG ) of the temperature sensor from the Formatting Interface Boardthe error code is changed to “dmd green - temperature sensoropen”.

Replace the whole Light Processor Unit. Contact Barco for furtherinstructions to repair the malfunction Light Processor Unit. It istoo critical to replace this temperature sensor in the field. Thereplacement of this temperature sensor must be done at factory orat an authorized service center.

SB

Wireunit of temperature sensor at the rear of the DMD of the blue channel.

SG

Wireunit of temperature sensor at the rear of the DMD of the green channel.

SR

Wireunit of temperature sensor at the rear of the DMD of the red channel.

TB

Wireunit of Peltier element at the rear of the DMD of the blue channel.

TG

Wireunit of Peltier element at the rear of the DMD of the green channel.

TR

Wireunit of Peltier element at the rear of the DMD of the red channel.

L

Wire unitof the temperature sensor on the cooling block at the light pipe entrance.

CA

Wireunit of the cat eye (contrast plate).

SH

Wireunit of the shutter.

LS

Wireunit of the light sensor inside the light pipe (behind the fold mirror).