Situation | Solution |
|---|---|
Wire unit (reference SR) of the temperature sensoris disconnected from the Formatting Interface Board. | Plug in the wire unit of the temperature sensor into its socketon the Formatting Interface Board. |
Damaged wire unit of the temperature sensor (Reference SR) which measures the temperature at therear side of the DMD of the red channel. |
|
Defect temperature sensor which measures the temperature atthe rear side of the DMD of the red channel. | Replace the whole Light Processor Unit. Contact Barco for furtherinstructions to repair the malfunction Light Processor Unit. It istoo critical to replace this temperature sensor in the field. Thereplacement of this temperature sensor must be done at factory orat an authorized service center. |
![]() | ||||||||||||||||||
|