Situation | Solution |
|---|---|
Blocked fan of the blue channel. | Check if the fan can turn freely. |
The wire unit of the temperature sensor (NTC) of the DMD inthe blue channel is disconnected from the Formatting Interface Board. | Check if the wire unit (reference SB) of the temperature sensor (NTC) of theDMD in the blue channel is connected with the Formatting InterfaceBoard. |
Defect temperature sensor which measures the temperature atthe rear side of the DMD of the blue channel. | Replace the whole Light Processor Unit. Contact Barco for furtherinstructions to repair the malfunction Light Processor Unit. It istoo critical to replace this temperature sensor in the field. Thereplacement of this temperature sensor must be done at factory orat an authorized service center. |
![]() | ||||||||||||||||||
|