Situation | Solution |
|---|---|
Wire unit (reference FC) of the SMPS fan disconnected. | Remove the left cover of the projector and check both connectionsof the SMPS fans. Note: SMPS fan 1 is the fan which is connected with the brownwire unit. SMPS fan 2 is the fan which is connected with the red wireunit. |
Wire unit of the fans and motor units (reference W) disconnected from the Power Backplane. | Remove the Input & Communication unit and check if the wireunit is inserted in the Power Backplane. |
Blocked fan. | Unblock the fan. Ensure that the fan can turn freely. |
Damaged wire unit. | Check if the wire unit of the fan is not damaged. Repair ifpossible, otherwise replace with new one. |
Fan end of life. | Replace the fan. See service manual chapter Power compartment left fan and Power compartment right fan. |
Malfunction Fan Control Board | Replace the Fan Control Board. |
Other fans are also not spinning. | Replace the SMPS Board. |
Defect Power Backplane | Replace the Power Backplane. |
![]() | ||||
|
![]() |